The gas installation and servicing should only be carried
out by an authorized, qualified person and must conform
to all relevant national and local regulations.
The gas supply system must incorporate a pressure
regulator to maintain a supply pressure of not more than
30 mbar.
A wall-mounted or floor-mounted shutoff valve of an
approved bottled-gas type must be incorporated in the
supply line in a position which is readily accessible to the
user.
If a hose connection is used, only tubing of the approved
type must be used. The length of the tube shall not
exceed 1,5 m.
The gas inlet tube should be connected at the rear to the
connection provided and be well secured with hose
clamps.
All completed connections should be checked for leaks
with soapy water.
DO NOT use a flame to check for gas leaks.
ELECTRICAL CONNECTION
The electrical installation must be carried out in a proper
and durable manner, taking into accounts all relevant
regulations and codes of practice.
For mains voltage operation, it is important that the
circuit is effectively earthed.
Mains Connection.
Check that the voltage stated on the data plate is the
same as the mains voltage in use.
Plug the refrigerator power cord into an easily accessible
earthed wall socket.
Electrical leads must be routed and secured so
that they cannot come into contact with hot or
sharp parts of the refrigerator.
From the side
At least 25 mm
From
above
Wall
Wall
Rear
25
25
25
6